Abstract

An innovative analysis method is proposed in this paper for the determination of ultimate resistance of prestressed concrete beams. The proposed method can be applied to simply supported or continuous beams in a unified manner whether structure and external loads are symmetric or not. Through the iterative nonlinear strain compatibility solutions, this method can also be applied to the non-prismatic section/un-symmetrical composite structures under moving load. The conventional studies have used the failure criteria when the strain of concrete reaches 0.003. However compared with bonded case, the value of strain in the reinforcement is much smaller than bonded case, thus, unbonded prestressed cases show compressive failure mode. It is shown that the proposed method gives acceptable results within 5% error compared with the prior experimental results. It can be shown that the proposed method can reach the solution much faster than typical three-dimensional finite element analysis for the same problem. This method is applicable to the existing unbonded prestressed members where deterioration has occurred leading to the reduced ultimate resistance or safety. In all, the proposed procedure can be applied to the design and analysis of newly constructed structures, as well as the risk assessment of rehabilitated structures.


결합되지 않은 프리스트레스 콘크리트의 궁극적 인 동작을위한 개선 된 해석 모델

조태준*, 김명한**
*정회원, 대진대학교 건설시스템공학과 부교수
**교신저자, 정회원, 국립목포대학교 건축공학과 부교수

초록


    1.Introduction1)

    Post-tensioned prestressed concrete (PSC, hereafter) structures have been successfully used for more than 40 years in the United States in a wide variety of constructions, including bridge construction, tanks, office buildings, hotels, parking structures, pavement, masonry structures, seismic resistant structural walls and foundation of residential houses. The flexibility of post-tensioning allows it to match exact design requirements with few limitations. The tendons in a post-tensioned system can be unbonded or bonded. In comparison with bonded tendons, unbonded mono strand systems are widely adopted in new construction sites, in terms of slabs, beams, joists, and mat foundations. Even if unbounded tendons are lighter, more flexible, and economical than conventional ones, they have replaced for new and existing structures internally or externally, they are not dealt rigorously in their ultimate behavior.

    The current ACI 318-08 equations1) for calculating the expected ultimate strength of unbonded tendons are mainly based on the experimental results. ACI 318-08 gives the following expression for the evaluation of ultimate strength of unbonded tendons:(1)

    f p s = f p e + 70 + f c 100 ρ p f p y or f p e + 420
    (1)

    where, fps is the stress in prestressed reinforcement at nominal strength (psi), fpe is the effective prestress after loss (psi), fc is 28th day compressive strength of concrete, and fpy is the specified yield strength of prestressing tendons in psi.

    Note that compressive strength of concrete is included in Eq. 1. Besides ACI method, there are two major approaches for the estimation of strain and stress of unbonded PSC members. These approaches, however, ignore the effect of concrete compressive strength. The first one is a simplified calculation of ultimate stress of prestressed steel based on the strain of steel in plastic deformed region2-5). The previous approaches2-5) require approximate assumption for the length of tendon subjected to plastic deformation, or require an assumed model for the partial bond strength between concrete and prestressed component, and inelastic strain of concrete.

    As stated above, most existing methods determine the ultimate strength of unbonded tendons by ignoring elastic deformations and only consider the contribution from the length of inelastic deformation, or require detailed three dimensional finite element modeling. In other words, most existing models have the following drawbacks:

    • 1) Elastic deformation of unbonded prestressed tendon is not considered.

    • 2) They are applicable only to symmetrical load, section, and boundary conditions. In other cases, computational expensive and time-consuming due to iterative three-dimensional finite element modeling is needed.

    • 3) can be assumed that balanced or tensile failure will always occur, which could lead to the unsafe design or evaluation, especially when concrete deteriorates thus compression failure prevails consisted of highly correlated composite elements.

    Due to the discrepancies between the assumed and real behavior of the failure mode of unbonded PSC beams, there are several problems when applying the current design specification to the deteriorated-unbonded PSC structures, which is damaged at the upper part of the girder or slab6-9).

    Reversely, the unbonded pressed concrete structures can be much more durable structures. By reinforcing compressive area, in which the equivalent compressive force is larger than equivalent tensile forces, the section would more endure than bonded one10),11).

    Accordingly, the main objectives of this study are:

    • 1) Identify strain and stress distributions of unbonded tendons, as well as deflection and ultimate resistance for varying compressive and tensile forces in an unbonded PSC section under external ultimate forces,

    • 2) Determine ultimate bending resistance for an asymmetric load and section or a non-prismatic section, which are commonly used in structures, and

    • 3) Validate the proposed iterative nonlinear section analysis method for unbonded PSC beams.

    2.Existing methods and proposed study

    It has been noted that prior studies for the analysis of ultimate bending resistance of unbonded PSC beams can only be applied to symmetrical sections and loadings2),3). Approximating and treating only plastic area 4, 5 in prismatic section under concentric loads or distributed loading conditions, the conventional methods cannot apply to moving load condition, non-prismatic section, composite structures, non-symmetric sections, and continuous beam boundary conditions. Consequently the approximation of assumptions could provide limited solutions, which are different with the real structures.

    Naaman and Alkhairi2),3) proposed a method for analysis of beams prestressed with external or unbonded tendons. To design unbonded prestressed structures in a simple equation using strain reduction factor, this can be applied to symmetric boundary condition and loading in the prismatic section of PSC structures1).

    Another important simplification to the existing methods was proposed by Haraji2) by assuming plastic deformation concentrated on the local area of the beam, which was further simplified by Carin et al.5) as shown in <Fig. 1> (a) and (b), respectively.

    As shown in <Fig. 1 (a)>, Haraji ignored small curvature variation in region of L-Lo, but focused on and only considered calculating the elongation of unbonded prestressed tendons in plastic deformed length of Lo. In a similar approximation, Carin et al ignored small strain increase in the elastic region and adopting Lp as:(2)

    f = L p c = 10.5
    (2)

    Where flexible length, f, is infinite for concentrated load at center point of simply supported beam, and f is 3 when two loads are at L/3 and 2L/3, and f is 6 for evenly distributed load case. L o L is 1.0 for bonded tendon case. in which Lp is the plastic deformed length, and c represents a selected constant.

    The plastic lengths used by the two approaches have some slight difference, as listed in <Table 1>.

    As compared in <Table 1>, the difference between the two previous approaches is the value of f. Haraji used three different values of f depending on the types of loading, but Carin et al suggested using the mean value of f as 10.5. It is well established that, in a steel member, the plastic deformed length f is the ratio of yielded moment(My) to the plastic moment(Mp):

    f = M y M p
    (3)

    The value, f in Eq. (3) depends on the geometry of the considered section. In other words, f of rectangular section is 1.5, and approximately 1.1 for I-shaped beams. The limitation of design specification show larger error if the compressive area of a section is damaged by any reasons. In fact, the compressive slab of simply supported beams may be the most vulnerable member to be attacked by chloride ion, water, live loads, temperature, and etc14).

    3.Proposed model for evaluation of ultimate strain in unbonded tendons

    For the evaluation of ultimate bending resistance of a unbonded PC beam, the total strain or stress of tendon is generally obtained using initial stress or strain with the additional stress or strain resulted from the external loads:(4)(5)

    f p s = f p e + Δ f p s
    (4)

    ε p s = ε p e + ε c e + Δ ε p s
    (5)

    where fps is the stress of prestressing steel, fpe is effective stress, Δfps is increased stress in prestressing steel over effective value, εps is the strain of prestressing steel, εpe is effective prestrain, εce is precompressive strain in the concrete at the level of prestressing steel, and Δεps is the increased strain in prestressing steel over effective value.

    The additional strain in steel due to external forces, Δεps , can be obtained by considering strain compatibility condition as shown in <Fig. 2>.

    In <Fig. 2>, ds is the depth of steel in the section, dps is the depth of prestressed tendons in section, c the length of neutral axis from top of the section, Ψ is the rotated angle defined as 1/curvature of the section, while ①, ②, and ③ illustrates the initial, decompression, and ultimate strain by the increased external moment, respectively.

    Shown at the lower part of the <Fig. 2>, the strain of bonded tendon is calculated by linear relationship of Δ ε p s , b o n d e d = ε c u · d p s c c , when compressive concrete strain reaches ε c u = 0.0014 f c . However unlike bonded prestressed case, due to the lack of bond between tendon and concrete, the unbonded prestressed tendons show much less strain and stress than bonded case at the ultimate state.

    In the present study, the total strain along the entire beam length is considered for the evaluation of ultimate stress and the resistance of unbonded PC members. For the purpose, the strain of steel is integrated in a form of:

    Δ ε i = M ( x ) · e ( x ) E c · I ( x )
    (6)

    where Δεiis the increased strain in prestressing steel over effective value of εpe , M (x) is external moment along axis, e (x) is the distance between prestressing steel to neutral axis, Ec is the modulus of elasticity for concrete, and I (x) is the moment of inertia for cracked or uncracked section.(7)

    Δ u n b o n d = i = 1 n 0 L i Δ ε i d x + i = 1 n 0 L o Δ ε i d x
    (7)

    Inserting axis-dependent external moment, the location of neutral axis, and crack depth-dependent moment of inertia allow the integration of strain in the divided lengths<Fig. 3>, the sum of which is utilized for the total strain of unbonded tendon in Eq. (6).

    Hence, including small deformations gives a more exact total deformation. Moreover, dividing sections removes the limitation of the approach to be applied in asymmetric section or non-prismatic section under asymmetric or moving load cases. In a conservative approach, the authors use a criterion for the length of plastically deformed part of a beam when the depth of neutral axis (c) is smaller than the depth of a section (dps ).

    The additional strain in prestressing steel over the effective value (Δεi) is integrated over the length L1 for the uncracked section (cdps ) and through the length (L2 ), for cracked inelastic area (c < dps ).

    The difference and improvements, compared with the existing approaches, are the total elongation of unbonded prestressed tendon calculated along the entire beam. The neutral axis depth (c) is obtained by iterative evaluation of force equilibrium with nonlinear constitutive relationship for concrete, mild steel reinforcement, and prestressing tendons, which is an expansion of previous models shown in the following Eq. (8) for Δεps , explained in <Table 2>.

    In <Table 2>, f is a coefficient dependent on the arrangement of loading. ∞ for single concentrated load, 3 for two third-point concentrated loads and 6 for uniform loading, Harajli2). Z is the shear span or the distance between the point of maximum moment and the point of contraflexure as shown in <Fig. 1 (a)>.

    Based on strain compatibility condition, even if the proposed equation needs nonlinear iterative analysis for longitudinal axis, it can be applied to constructed, deteriorated, and asymmetric section and loads in a unified way, which has been approximated or could not applied to deteriorated structures.

    4.Procedure for calculation of the interactive nonlinear section analysis

    For the calculation of a resistance of a section, constitutive relationships for prestressed and non-prestressed reinforcement, concrete are used for compressive and tensile force calculation at each increased steps of strain in the top of concrete section. The computation procedure is summarized in the flowchart of <Fig. 4>.

    In <Fig. 4>, c is a neutral axis depth, εc is a given strain of the concrete section, Φ = ε c c is the curvature, C is a total compressive force ( σ a υ b c = α f c b c ), b is a bay of the section, T is total tensile force of a section, α represents the ratio of average stress to compressive concrete strength ( σ a υ f c ), and βc gives a centroid of area of strain energy.

    As shown in the flowchart of proposed iterative nonlinear section analysis, L p varies depending on the degree or type of deterioration, for example partial corrosion, fire, freeze thaw or any other accidental damages.

    Intentional reinforce at the compression area in the design step or as a rehabilitation, the capacity and maintenance schedule need to be determined based on the exact prediction of ultimate strength, in which can predict the value under asymmetric load in non-prismatic sections.

    5.Validation for unbonded PSC members

    Proposed procedure was compared with the Tan et al.’s experimental results15). Properties of target PSC bridge is presented in <Table 3>.

    As shown in <Table 4>, the average comparative results of ultimate resistance moment for 6 test beams are lower than 5% difference. The proposed procedures are applied for varying depth of composite girders and span length from 1.5 to 9 meters for model of Beam T-1<Table 3, 4>. While span/depth ratio increases from 7.5 to 45, the increased stress in unbonded tendon until section failed is decreased from 553.14 to 285.90MPa, depicted in <Fig. 5>.

    6.Concluding remarks

    The previous models have focused on the approximate evaluations of deformation of unbonded tendons at the plastically deformed location. However, the studies have ignored the distribution of strain of unbonded prestressed steel along the longitudinal axis, and the conventional models are limited to symmetric section and loading. In other words, it needs tremendous time for modeling and analysis of 3 dimensional finite element model discourages for adopting at design, which could not analyze partly damaged members, which are common in the existing structure.

    The proposed model in this paper for the determination of ultimate resistance of prestressed concrete beams can be applied to simply supported or continuous beams in a unified manner whether structure and external loads is symmetric or not. Through iterative nonlinear strain compatibility solutions, it can also be applied to non-prismatic section or asymmetric composite structures under moving load. The proposed method gives acceptable results as less than 5% differences, compared with the prior experimental results. The results are also applicable to existing unbonded prestressed members where deterioration has occurred leading to the reduced ultimate resistance or safety. Consequently, the proposed procedure can be applied to the design and analysis of newly constructed structures, as well as the risk assessment of rehabilitated structures.

    Figure

    KASS-17-149_F1.gif

    An existing ultimate deformation model

    KASS-17-149_F2.gif

    Strain compatibility condition for PSC section by bonded or unbonded tendons

    KASS-17-149_F3.gif

    Integral contour for evaluating total strain

    KASS-17-149_F4.gif

    Flow chart for nonlinear analysis for un-cracked / cracked section

    KASS-17-149_F5.gif

    Stresses in tendon while varying (a) depth and (b) span length

    Table

    Comparison for the considered plastic deformed lengths

    *Following Mattock et al.12)
    **Following Carin et al.13)

    Summarizes the main discrepancies between Haraji’s approach with the present study

    *Lp = f(time, fc, corrosion, accidental damage)

    The properties of target PSC girder bridge

    Calculated results compared with experiments

    Reference

    1. ACI Committee 318 (2007) Building Code Requirements for Reinforced Concrete, American Concrete Institute,
    2. HarajliM H KanjM Y (1991) “Ultimate Flexural Strength of Concrete Members Prestressed with Unbonded Tendons” , ACI Structural Journal, Vol.88 (6) ; pp. 663-673
    3. NaamanAntonine E AlkhairiFadi M (1991) “Stress at Ultimate in Unbonded Post- Tensioning Tendons: Part 1-Evaluation of the State-of-the- Art” , ACI Structural Journal, Vol.88 (5) ; pp. 641-651
    4. NaamanAntonine E AlkhairiFadi M (1991) “Stress at Ultimate in Unbonded Post- Tensioning Tendons: Part 2-Proposed Methodology” , ACI Structural Journal, Vol.88 (6) ; pp. 683-692
    5. OhByung-Hwan YooSung-Won (1999) "Prediction of Prestressing Steel Stress at Ultimate State of PSC Members with Externak Unbonded Tendons" , KCI Journal, Vol.11 (6)
    6. DuGongchen TaoXuekang (1985) “Ultimate Stress of Unbonded Tendons in Partially PSC Beams” , PCI Journal, Vol.30 (6) ; pp. 72-91
    7. ChakrabartiP R (1995) “Ultimate Stress for Unbonded Post-Tensioning Tendons in Partially Prestressed Beams” , ACI Structural Journal, Vol.92 (6) ; pp. 689-697
    8. ChakrabartiP R WhangT P BrownW ArsadK M AmezeuaE (1994) “Unbonded Post-Tensioning Tendons and Partially Prestressed Beams” , ACI Structural Journal, Vol.91 (5) ; pp. 1-10
    9. CampbellT Ivan ChouinardKevin L (1991) “Influence of Nonprestressed Reinforcement on the Strength of Unbonded Partially PSC Members” , ACI Structural Journal, Vol.88 (5) ; pp. 546-551
    10. MirzaS A MacGregorJ O (1979) “Variations in Dimensions of Reinforced Concrete Members” , Journal of the Structural Division ASCE, Vol.105 (5T4)
    11. MirzaS A SkrabekB W (1992) “Statistical Analysis of Slender Composite Beam Column Strength” , Journal of Structural Engineering, Vol.118 (5) ; pp. 1312-1332
    12. MattokA H YamazakiJ KtulaB (1971) Comparative Study of PSC Beams With and Without Bond , ACI Journal, Proceedings, Vol.68 (2) ; pp.116-125
    13. CarinL Roberts-Wollmann MichaelE Kreger DavidM Rogowsky JohnE Breen (2004) ACI STRUCTURAL JOURNAL TECHNICAL PAPER, Titltle no. 102-S20,
    14. TvergaardV NeedlemanA (1984) “Analysis of the cup-cone fracture in a round tensile bar” , Acta Metallurgica, Vol.32 (1) ; pp.157-169
    15. TanKH NgCK (1997) Effects of deviators and tendon configuration on behaviour of externally prestressed beams , ACI Structural Journal, Vol.94 (1) ; pp.13-22